Print ISSN:-2394-2789

Online ISSN:-2394-2797

CODEN : IJPCN9




Downlaod Files

   


Article Access statistics

Viewed: 1531

PDF Downloaded: 600


Stability Indicating RP-HPLC Method for In-Vitro Analysis of 5-Flurouracil


Full Text PDF


Original Article

Author Details : Md. Habban Akhter, Saima Amin, Showkat R Mir

Volume : 3, Issue : 1, Year : 2016

Article Page : 18-24


Suggest article by email

Get Permission

Abstract

5-Flurouracil (FU), {5-fluoropyrimidines-2,4(1H,3H)-dione} is an anticancer drug that competitively inhibits thymidylate synthatase, an enzyme required for DNA synthesis that leads to programmed cell death of proliferating cells. It is used as topical cream for squamous cell carcinoma but a little information is available for its active drug targeting. Our attempt is to generate a validated stability indicating RP-HPLC method for the quantitation of 5-FU for active targeting to squamous cell carcinoma. In our study, RP-HPLC system used was (SHIMADZU (AT vp), Japan) and comprised of UV detector (SCL-10A vp), a pump system (LC-10 AT vp), and an injector. The separation was achieved on C18 LiChrospher®100 (250 x 4.6 mm, 5 ?m) and elution was monitored gradiently with mobile phase consisting of HPLC water at a flow rate of 1ml/min. The injection volume was 20 µL previously filtered through 0.45? membrane filter and elute was analyzed at the set wavelength of 269 nm. The proposed method was validated for various parameters such as specificity, linearity, precision, accuracy, and robustness. The calibration plot drawn was found to be linear over the concentration range of 1–10µg/mL and within the acceptable range (R2 = 0.999). The developed method was found to be simple, precise, and accurate and can be reproduced with LOD and LOQ of 0.007108 and 0.021539µg/mL respectively. The degradation study at variable temperatures such as 0oC; 8oC, 25oC, 37oC and pH 1.2, 3.2, 4.2, 6.8 and 7.4 after storage for 24 h suggested that 5-FU was stable at aforementioned temperatures and pH. It further signifies that the method is suitable for in-process quality control analysis of new composition of 5- FU due to good accuracy and high degree of precision.

Keywords: 5-Fluorouracil, Active targeting, Assay validation, RP-HPLC, Squamous cell carcinoma, Solubility



How to cite : Akhter M H, Amin S, Mir S R, Stability Indicating RP-HPLC Method for In-Vitro Analysis of 5-Flurouracil. Int J Pharm Chem Anal 2016;3(1):18-24


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.